ADDRESS LIST Modbus Programming Manual
44 Version 2
Copyright © 2012 by Despatch Industries.
All rights reserved. No part of the contents of this manual may be reproduced, copied or transmitted in any form or by any
means including graphic, electronic, or mechanical methods or photocopying, recording, or information storage and
retrieval systems without the written permission of Despatch Industries, unless for purchaser's personal use.
2.9.5.7. Deleting a Segment (Command Code DS)
The delete segment command deletes the specified segment from the specified profile. The
following segments are moved up one place in the profile (e.g. if segment 6 is deleted segment 7
now becomes segment 6).
Delete A Segment - Request (to instrument)
The ID address of the instrument
Requires the multi read/write function
Read Start Address High Byte
Read Start Address Low Byte
Read Quantity Of Registers High
Read Quantity Of Registers Low
Write Quantity Of Registers High
Write Quantity Of Registers Low
Number of the profile that the segment
wants to be deleted from
Number of the segment that wants to be
deleted
The instrument replies to this message with an Edit Response Message Section 2.9.5.9.
2.9.5.8. Getting the Number of Segments Remaining (Command Code SR)
Returns the number of unused segments remaining in the instrument. The number will be
between 0 and 255, depending on how many have been used in the profiles so far created.
Get Segments Remaining - Request (to instrument)
The ID address of the instrument as required
Requires the multi read/write function
Read Start Address High Byte
Read Start Address Low Byte
Read Quantity Of Registers High
Read Quantity Of Registers Low
Write Quantity Of Registers High
Write Quantity Of Registers Low